Double Pipe Heat Exchanger Design 2.1.0.2
DHex is a software tool that is made to demonstrate the chemical design calculations of Double pipe (hairpin) Heat Exchangers.The software will do all the thermal calculations involved in the design and will generate a summary of all results..etc
Last update
17 Jul. 2017
Licence
Free to try
OS Support
Windows
Downloads
Total: 813 | Last week: 6
Ranking
#526 in
Applications
Publisher
Webbusterz Engineering Software
Screenshots of Double Pipe Heat Exchanger Design
Double Pipe Heat Exchanger Design Publisher's Description
-Software Features-
+Step by step calculation
+Support S.I & English (U.S) Units of measurement.
+Ability to import properties to Hot/Cold sides from Microsoft Excel.
+Save/Load results
+Export Results to Microsoft Excel Engineering Datasheet
-Calculations-
+Calculate unknown Cold or Hot side temperatures.
+Perform thermal analysis for bare tube double pipe (hairpin) heat exchangers.
+Perform thermal analysis for finned tube double pipe (hairpin) heat exchangers.
+Choose from Counter Current or Co-Current Flow arrangement
+Choose from Series arrangement or Series-Parallel arrangement.
+The software will also tell you the location of Hot/Cold fluids within the heat exchanger (Inner Pipe or Outer Pipe).
+Select from different correlations to calculate Cold/Hot side heat transfer coefficient. Also the ability to adjust Nusselt number if you do have a different correlation.
+Calculate the Area, Flow area, Length, Log Mean Temperature Difference, Number of Hairpins, Unknown Flow rate.
+Calculate the scale resistance (dirt factor), Equivalent Diameter.
+Calculate Pipe/Annulus side Reynolds, Nusselt numbers & Prandtl Numbers.
+Duty, Clean and Design Overall heat transfer coefficient calculations
+Pipe/Annulus velocities and Mass velocity calculations
+Number of Transfer Units & Thermal Capacity ratio calculation.
+Clean and Fouled Fin Efficiency calculations for finned tube heat exchanger.
+Pressure drop calculations & Entrance and Exit losses.
-Databases
+Physical properties estimation of pure components for more than 1450 components; the database has the ability to estimate Thermal Conductivity, Density, Heat Capacity and Viscosity. The database also included & come as a standalone interface but easily integrated with the software.
+Estimate mixture properties. (ALL ESTIMATION METHODS CURRENTLY SUPPORT LIQUIDS ONLY)
+User database functions to allow user to add/delete components and load to hot/cold side (Empty database!)
+Fouling factors
+Step by step calculation
+Support S.I & English (U.S) Units of measurement.
+Ability to import properties to Hot/Cold sides from Microsoft Excel.
+Save/Load results
+Export Results to Microsoft Excel Engineering Datasheet
-Calculations-
+Calculate unknown Cold or Hot side temperatures.
+Perform thermal analysis for bare tube double pipe (hairpin) heat exchangers.
+Perform thermal analysis for finned tube double pipe (hairpin) heat exchangers.
+Choose from Counter Current or Co-Current Flow arrangement
+Choose from Series arrangement or Series-Parallel arrangement.
+The software will also tell you the location of Hot/Cold fluids within the heat exchanger (Inner Pipe or Outer Pipe).
+Select from different correlations to calculate Cold/Hot side heat transfer coefficient. Also the ability to adjust Nusselt number if you do have a different correlation.
+Calculate the Area, Flow area, Length, Log Mean Temperature Difference, Number of Hairpins, Unknown Flow rate.
+Calculate the scale resistance (dirt factor), Equivalent Diameter.
+Calculate Pipe/Annulus side Reynolds, Nusselt numbers & Prandtl Numbers.
+Duty, Clean and Design Overall heat transfer coefficient calculations
+Pipe/Annulus velocities and Mass velocity calculations
+Number of Transfer Units & Thermal Capacity ratio calculation.
+Clean and Fouled Fin Efficiency calculations for finned tube heat exchanger.
+Pressure drop calculations & Entrance and Exit losses.
-Databases
+Physical properties estimation of pure components for more than 1450 components; the database has the ability to estimate Thermal Conductivity, Density, Heat Capacity and Viscosity. The database also included & come as a standalone interface but easily integrated with the software.
+Estimate mixture properties. (ALL ESTIMATION METHODS CURRENTLY SUPPORT LIQUIDS ONLY)
+User database functions to allow user to add/delete components and load to hot/cold side (Empty database!)
+Fouling factors
What's New in Version 2.1.0.2 of Double Pipe Heat Exchanger Design
Added export to Microsoft Excel 97/2003 Engineering datasheet, now you can choose to export to either Microsoft Excel 2007/2010 or older excel versions, Corrected a bug in the loading module causes the software not
Look for Similar Items by Category
Feedback
- If you need help or have a question, contact us
- Would you like to update this product info?
- Is there any feedback you would like to provide? Click here
Popular Downloads
- Kundli 4.5
- Grand Auto Adventure 1.0
- Macromedia Flash 8 8.0
- Grand Theft Auto: Vice City 1.0
- Cool Edit Pro 2.1.3097.0
- Hill Climb Racing 1.0
- Cheat Engine 6.8.1
- Tom VPN 2.2.8
- Horizon 2.9.0.0
- Vector on PC 1.0
- Iggle Pop 1.0
- MKV Player 2.1.23
- Zuma Deluxe 1.0
- Windows XP Service Pack 3 Build...
- Minecraft 1.10.2
- Ulead Video Studio Plus 11
- Netcut 2.1.4
- Euro Truck Simulator 1.3b
- C-Free 5.0
- Auto-Tune Evo VST 6.0.9.2